Frankford Arsenal X-10 Press ~ #6 Die Station Setup

Published on August 28, 2023
Duration: 53:39

This guide details the initial setup of the case feeder for the Frankford Arsenal X-10 progressive reloading press. It covers adjusting the collator assembly, sliding gate, and speed control to ensure proper case orientation and feeding. The instructor emphasizes the importance of following manual instructions and provides a method to catch misoriented cases before they enter the main mechanism.

Quick Summary

To adjust the case feeder on the Frankford Arsenal X-10, loosen the collator's thumb nut, set the sliding gate fully left for pistol or rifle cases, place cases in the collator, and adjust the speed control to an intermediate setting. Fine-tune the speed until cases feed smoothly and oriented correctly. A method to catch misoriented cases involves slightly lifting the collator tube.

Chapters

  1. 00:01Introduction and Press Setup
  2. 01:34Press History and Controversies
  3. 03:02Importance of Reloading Manual
  4. 04:39Station 1: Case Feed Adjustment
  5. 07:15Testing Case Feeder Adjustment
  6. 08:03Tool Head Configuration Overview
  7. 12:54First Case Setup and Lubrication
  8. 15:36Station 2: Universal Decapping Die Setup
  9. 16:22Station 3: Sizing Die Setup
  10. 17:50Sizing Die Adjustment Details
  11. 20:08Checking Sized Case with Chamber Gauge
  12. 21:02Adjusting Depth Stop
  13. 23:20Station 4: Swaging Station Setup
  14. 30:04Station 5: Priming Station Setup
  15. 32:56Testing Primer Seating
  16. 38:18Case Control Tab Adjustment
  17. 40:26Station 6: Powder Charging (Deflector Removal)
  18. 43:32Station 7: Powder Measure Setup
  19. 47:22Adjusting Powder Charge
  20. 49:51Powder Measure Reset Rod Adjustment
  21. 50:51Station 8: Bullet Seating Station Setup
  22. 52:43Station 9/10: Factory Crimp Die Setup
  23. 52:55Press Setup Complete & Conclusion

Frequently Asked Questions

How do you adjust the case feeder on the Frankford Arsenal X-10 press?

To adjust the case feeder, loosen the collator's thumb nut, set the sliding gate fully left for pistol or rifle cases, place cases in the collator, and adjust the speed control to an intermediate setting. Fine-tune the speed until cases feed smoothly and oriented correctly.

What is the purpose of the sliding gate on the X-10's case feeder?

The sliding gate on the Frankford Arsenal X-10's case feeder is used to control the flow of cases. It should be adjusted fully to the left (closed) for both pistol and rifle cases to ensure proper feeding into the collator.

How can I prevent misoriented cases from entering the reloading press mechanism?

You can prevent misoriented cases by slightly lifting the collator tube on the Frankford Arsenal X-10's case feeder. This allows the tube to rest on the case feeder mechanism, catching any improperly oriented cases before they drop further.

What are the initial setup steps for the Frankford Arsenal X-10's case feeder?

Initial setup involves loosening the collator's thumb nut, setting the sliding gate to the far left, adding cases, and adjusting the speed control to an intermediate setting. The goal is smooth, base-down case feeding.

More Gunsmithing & DIY Videos You Might Like

More from GunBlue490

View all →